GNU Linux-libre 4.19.264-gnu1
[releases.git] / drivers / net / ethernet / freescale / fman / Kconfig
1 config FSL_FMAN
2         tristate "FMan support"
3         depends on FSL_SOC || ARCH_LAYERSCAPE || COMPILE_TEST
4         select GENERIC_ALLOCATOR
5         select PHYLIB
6         default n
7         help
8                 Freescale Data-Path Acceleration Architecture Frame Manager
9                 (FMan) support
10
11 config DPAA_ERRATUM_A050385
12         bool
13         depends on ARM64 && FSL_DPAA
14         default y
15         help
16                 DPAA FMan erratum A050385 software workaround implementation:
17                 align buffers, data start, SG fragment length to avoid FMan DMA
18                 splits.
19                 FMAN DMA read or writes under heavy traffic load may cause FMAN
20                 internal resource leak thus stopping further packet processing.
21                 The FMAN internal queue can overflow when FMAN splits single
22                 read or write transactions into multiple smaller transactions
23                 such that more than 17 AXI transactions are in flight from FMAN
24                 to interconnect. When the FMAN internal queue overflows, it can
25                 stall further packet processing. The issue can occur with any
26                 one of the following three conditions:
27                 1. FMAN AXI transaction crosses 4K address boundary (Errata
28                 A010022)
29                 2. FMAN DMA address for an AXI transaction is not 16 byte
30                 aligned, i.e. the last 4 bits of an address are non-zero
31                 3. Scatter Gather (SG) frames have more than one SG buffer in
32                 the SG list and any one of the buffers, except the last
33                 buffer in the SG list has data size that is not a multiple
34                 of 16 bytes, i.e., other than 16, 32, 48, 64, etc.
35                 With any one of the above three conditions present, there is
36                 likelihood of stalled FMAN packet processing, especially under
37                 stress with multiple ports injecting line-rate traffic.