GNU Linux-libre 4.19.286-gnu1
[releases.git] / drivers / staging / nvec / nvec_power.c
1 // SPDX-License-Identifier: GPL-2.0
2 /*
3  * nvec_power: power supply driver for a NVIDIA compliant embedded controller
4  *
5  * Copyright (C) 2011 The AC100 Kernel Team <ac100@lists.launchpad.net>
6  *
7  * Authors:  Ilya Petrov <ilya.muromec@gmail.com>
8  *           Marc Dietrich <marvin24@gmx.de>
9  */
10
11 #include <linux/module.h>
12 #include <linux/platform_device.h>
13 #include <linux/err.h>
14 #include <linux/power_supply.h>
15 #include <linux/slab.h>
16 #include <linux/workqueue.h>
17 #include <linux/delay.h>
18
19 #include "nvec.h"
20
21 #define GET_SYSTEM_STATUS 0x00
22
23 struct nvec_power {
24         struct notifier_block notifier;
25         struct delayed_work poller;
26         struct nvec_chip *nvec;
27         int on;
28         int bat_present;
29         int bat_status;
30         int bat_voltage_now;
31         int bat_current_now;
32         int bat_current_avg;
33         int time_remain;
34         int charge_full_design;
35         int charge_last_full;
36         int critical_capacity;
37         int capacity_remain;
38         int bat_temperature;
39         int bat_cap;
40         int bat_type_enum;
41         char bat_manu[30];
42         char bat_model[30];
43         char bat_type[30];
44 };
45
46 enum {
47         SLOT_STATUS,
48         VOLTAGE,
49         TIME_REMAINING,
50         CURRENT,
51         AVERAGE_CURRENT,
52         AVERAGING_TIME_INTERVAL,
53         CAPACITY_REMAINING,
54         LAST_FULL_CHARGE_CAPACITY,
55         DESIGN_CAPACITY,
56         CRITICAL_CAPACITY,
57         TEMPERATURE,
58         MANUFACTURER,
59         MODEL,
60         TYPE,
61 };
62
63 enum {
64         AC,
65         BAT,
66 };
67
68 struct bat_response {
69         u8 event_type;
70         u8 length;
71         u8 sub_type;
72         u8 status;
73         /* payload */
74         union {
75                 char plc[30];
76                 u16 plu;
77                 s16 pls;
78         };
79 };
80
81 static struct power_supply *nvec_bat_psy;
82 static struct power_supply *nvec_psy;
83
84 static int nvec_power_notifier(struct notifier_block *nb,
85                                unsigned long event_type, void *data)
86 {
87         struct nvec_power *power =
88             container_of(nb, struct nvec_power, notifier);
89         struct bat_response *res = data;
90
91         if (event_type != NVEC_SYS)
92                 return NOTIFY_DONE;
93
94         if (res->sub_type == 0) {
95                 if (power->on != res->plu) {
96                         power->on = res->plu;
97                         power_supply_changed(nvec_psy);
98                 }
99                 return NOTIFY_STOP;
100         }
101         return NOTIFY_OK;
102 }
103
104 static const int bat_init[] = {
105         LAST_FULL_CHARGE_CAPACITY, DESIGN_CAPACITY, CRITICAL_CAPACITY,
106         MANUFACTURER, MODEL, TYPE,
107 };
108
109 static void get_bat_mfg_data(struct nvec_power *power)
110 {
111         int i;
112         char buf[] = { NVEC_BAT, SLOT_STATUS };
113
114         for (i = 0; i < ARRAY_SIZE(bat_init); i++) {
115                 buf[1] = bat_init[i];
116                 nvec_write_async(power->nvec, buf, 2);
117         }
118 }
119
120 static int nvec_power_bat_notifier(struct notifier_block *nb,
121                                    unsigned long event_type, void *data)
122 {
123         struct nvec_power *power =
124             container_of(nb, struct nvec_power, notifier);
125         struct bat_response *res = data;
126         int status_changed = 0;
127
128         if (event_type != NVEC_BAT)
129                 return NOTIFY_DONE;
130
131         switch (res->sub_type) {
132         case SLOT_STATUS:
133                 if (res->plc[0] & 1) {
134                         if (power->bat_present == 0) {
135                                 status_changed = 1;
136                                 get_bat_mfg_data(power);
137                         }
138
139                         power->bat_present = 1;
140
141                         switch ((res->plc[0] >> 1) & 3) {
142                         case 0:
143                                 power->bat_status =
144                                     POWER_SUPPLY_STATUS_NOT_CHARGING;
145                                 break;
146                         case 1:
147                                 power->bat_status =
148                                     POWER_SUPPLY_STATUS_CHARGING;
149                                 break;
150                         case 2:
151                                 power->bat_status =
152                                     POWER_SUPPLY_STATUS_DISCHARGING;
153                                 break;
154                         default:
155                                 power->bat_status = POWER_SUPPLY_STATUS_UNKNOWN;
156                         }
157                 } else {
158                         if (power->bat_present == 1)
159                                 status_changed = 1;
160
161                         power->bat_present = 0;
162                         power->bat_status = POWER_SUPPLY_STATUS_UNKNOWN;
163                 }
164                 power->bat_cap = res->plc[1];
165                 if (status_changed)
166                         power_supply_changed(nvec_bat_psy);
167                 break;
168         case VOLTAGE:
169                 power->bat_voltage_now = res->plu * 1000;
170                 break;
171         case TIME_REMAINING:
172                 power->time_remain = res->plu * 3600;
173                 break;
174         case CURRENT:
175                 power->bat_current_now = res->pls * 1000;
176                 break;
177         case AVERAGE_CURRENT:
178                 power->bat_current_avg = res->pls * 1000;
179                 break;
180         case CAPACITY_REMAINING:
181                 power->capacity_remain = res->plu * 1000;
182                 break;
183         case LAST_FULL_CHARGE_CAPACITY:
184                 power->charge_last_full = res->plu * 1000;
185                 break;
186         case DESIGN_CAPACITY:
187                 power->charge_full_design = res->plu * 1000;
188                 break;
189         case CRITICAL_CAPACITY:
190                 power->critical_capacity = res->plu * 1000;
191                 break;
192         case TEMPERATURE:
193                 power->bat_temperature = res->plu - 2732;
194                 break;
195         case MANUFACTURER:
196                 memcpy(power->bat_manu, &res->plc, res->length - 2);
197                 power->bat_model[res->length - 2] = '\0';
198                 break;
199         case MODEL:
200                 memcpy(power->bat_model, &res->plc, res->length - 2);
201                 power->bat_model[res->length - 2] = '\0';
202                 break;
203         case TYPE:
204                 memcpy(power->bat_type, &res->plc, res->length - 2);
205                 power->bat_type[res->length - 2] = '\0';
206                 /*
207                  * This differs a little from the spec fill in more if you find
208                  * some.
209                  */
210                 if (!strncmp(power->bat_type, "Li", 30))
211                         power->bat_type_enum = POWER_SUPPLY_TECHNOLOGY_LION;
212                 else
213                         power->bat_type_enum = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
214                 break;
215         default:
216                 return NOTIFY_STOP;
217         }
218
219         return NOTIFY_STOP;
220 }
221
222 static int nvec_power_get_property(struct power_supply *psy,
223                                    enum power_supply_property psp,
224                                    union power_supply_propval *val)
225 {
226         struct nvec_power *power = dev_get_drvdata(psy->dev.parent);
227
228         switch (psp) {
229         case POWER_SUPPLY_PROP_ONLINE:
230                 val->intval = power->on;
231                 break;
232         default:
233                 return -EINVAL;
234         }
235         return 0;
236 }
237
238 static int nvec_battery_get_property(struct power_supply *psy,
239                                      enum power_supply_property psp,
240                                      union power_supply_propval *val)
241 {
242         struct nvec_power *power = dev_get_drvdata(psy->dev.parent);
243
244         switch (psp) {
245         case POWER_SUPPLY_PROP_STATUS:
246                 val->intval = power->bat_status;
247                 break;
248         case POWER_SUPPLY_PROP_CAPACITY:
249                 val->intval = power->bat_cap;
250                 break;
251         case POWER_SUPPLY_PROP_PRESENT:
252                 val->intval = power->bat_present;
253                 break;
254         case POWER_SUPPLY_PROP_VOLTAGE_NOW:
255                 val->intval = power->bat_voltage_now;
256                 break;
257         case POWER_SUPPLY_PROP_CURRENT_NOW:
258                 val->intval = power->bat_current_now;
259                 break;
260         case POWER_SUPPLY_PROP_CURRENT_AVG:
261                 val->intval = power->bat_current_avg;
262                 break;
263         case POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW:
264                 val->intval = power->time_remain;
265                 break;
266         case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
267                 val->intval = power->charge_full_design;
268                 break;
269         case POWER_SUPPLY_PROP_CHARGE_FULL:
270                 val->intval = power->charge_last_full;
271                 break;
272         case POWER_SUPPLY_PROP_CHARGE_EMPTY:
273                 val->intval = power->critical_capacity;
274                 break;
275         case POWER_SUPPLY_PROP_CHARGE_NOW:
276                 val->intval = power->capacity_remain;
277                 break;
278         case POWER_SUPPLY_PROP_TEMP:
279                 val->intval = power->bat_temperature;
280                 break;
281         case POWER_SUPPLY_PROP_MANUFACTURER:
282                 val->strval = power->bat_manu;
283                 break;
284         case POWER_SUPPLY_PROP_MODEL_NAME:
285                 val->strval = power->bat_model;
286                 break;
287         case POWER_SUPPLY_PROP_TECHNOLOGY:
288                 val->intval = power->bat_type_enum;
289                 break;
290         default:
291                 return -EINVAL;
292         }
293         return 0;
294 }
295
296 static enum power_supply_property nvec_power_props[] = {
297         POWER_SUPPLY_PROP_ONLINE,
298 };
299
300 static enum power_supply_property nvec_battery_props[] = {
301         POWER_SUPPLY_PROP_STATUS,
302         POWER_SUPPLY_PROP_PRESENT,
303         POWER_SUPPLY_PROP_CAPACITY,
304         POWER_SUPPLY_PROP_VOLTAGE_NOW,
305         POWER_SUPPLY_PROP_CURRENT_NOW,
306 #ifdef EC_FULL_DIAG
307         POWER_SUPPLY_PROP_CURRENT_AVG,
308         POWER_SUPPLY_PROP_TEMP,
309         POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW,
310 #endif
311         POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,
312         POWER_SUPPLY_PROP_CHARGE_FULL,
313         POWER_SUPPLY_PROP_CHARGE_EMPTY,
314         POWER_SUPPLY_PROP_CHARGE_NOW,
315         POWER_SUPPLY_PROP_MANUFACTURER,
316         POWER_SUPPLY_PROP_MODEL_NAME,
317         POWER_SUPPLY_PROP_TECHNOLOGY,
318 };
319
320 static char *nvec_power_supplied_to[] = {
321         "battery",
322 };
323
324 static const struct power_supply_desc nvec_bat_psy_desc = {
325         .name = "battery",
326         .type = POWER_SUPPLY_TYPE_BATTERY,
327         .properties = nvec_battery_props,
328         .num_properties = ARRAY_SIZE(nvec_battery_props),
329         .get_property = nvec_battery_get_property,
330 };
331
332 static const struct power_supply_desc nvec_psy_desc = {
333         .name = "ac",
334         .type = POWER_SUPPLY_TYPE_MAINS,
335         .properties = nvec_power_props,
336         .num_properties = ARRAY_SIZE(nvec_power_props),
337         .get_property = nvec_power_get_property,
338 };
339
340 static int counter;
341 static int const bat_iter[] = {
342         SLOT_STATUS, VOLTAGE, CURRENT, CAPACITY_REMAINING,
343 #ifdef EC_FULL_DIAG
344         AVERAGE_CURRENT, TEMPERATURE, TIME_REMAINING,
345 #endif
346 };
347
348 static void nvec_power_poll(struct work_struct *work)
349 {
350         char buf[] = { NVEC_SYS, GET_SYSTEM_STATUS };
351         struct nvec_power *power = container_of(work, struct nvec_power,
352                                                 poller.work);
353
354         if (counter >= ARRAY_SIZE(bat_iter))
355                 counter = 0;
356
357         /* AC status via sys req */
358         nvec_write_async(power->nvec, buf, 2);
359         msleep(100);
360
361         /*
362          * Select a battery request function via round robin doing it all at
363          * once seems to overload the power supply.
364          */
365         buf[0] = NVEC_BAT;
366         buf[1] = bat_iter[counter++];
367         nvec_write_async(power->nvec, buf, 2);
368
369         schedule_delayed_work(to_delayed_work(work), msecs_to_jiffies(5000));
370 };
371
372 static int nvec_power_probe(struct platform_device *pdev)
373 {
374         struct power_supply **psy;
375         const struct power_supply_desc *psy_desc;
376         struct nvec_power *power;
377         struct nvec_chip *nvec = dev_get_drvdata(pdev->dev.parent);
378         struct power_supply_config psy_cfg = {};
379
380         power = devm_kzalloc(&pdev->dev, sizeof(struct nvec_power), GFP_NOWAIT);
381         if (!power)
382                 return -ENOMEM;
383
384         dev_set_drvdata(&pdev->dev, power);
385         power->nvec = nvec;
386
387         switch (pdev->id) {
388         case AC:
389                 psy = &nvec_psy;
390                 psy_desc = &nvec_psy_desc;
391                 psy_cfg.supplied_to = nvec_power_supplied_to;
392                 psy_cfg.num_supplicants = ARRAY_SIZE(nvec_power_supplied_to);
393
394                 power->notifier.notifier_call = nvec_power_notifier;
395
396                 INIT_DELAYED_WORK(&power->poller, nvec_power_poll);
397                 schedule_delayed_work(&power->poller, msecs_to_jiffies(5000));
398                 break;
399         case BAT:
400                 psy = &nvec_bat_psy;
401                 psy_desc = &nvec_bat_psy_desc;
402
403                 power->notifier.notifier_call = nvec_power_bat_notifier;
404                 break;
405         default:
406                 return -ENODEV;
407         }
408
409         nvec_register_notifier(nvec, &power->notifier, NVEC_SYS);
410
411         if (pdev->id == BAT)
412                 get_bat_mfg_data(power);
413
414         *psy = power_supply_register(&pdev->dev, psy_desc, &psy_cfg);
415
416         return PTR_ERR_OR_ZERO(*psy);
417 }
418
419 static int nvec_power_remove(struct platform_device *pdev)
420 {
421         struct nvec_power *power = platform_get_drvdata(pdev);
422
423         cancel_delayed_work_sync(&power->poller);
424         nvec_unregister_notifier(power->nvec, &power->notifier);
425         switch (pdev->id) {
426         case AC:
427                 power_supply_unregister(nvec_psy);
428                 break;
429         case BAT:
430                 power_supply_unregister(nvec_bat_psy);
431         }
432
433         return 0;
434 }
435
436 static struct platform_driver nvec_power_driver = {
437         .probe = nvec_power_probe,
438         .remove = nvec_power_remove,
439         .driver = {
440                    .name = "nvec-power",
441         }
442 };
443
444 module_platform_driver(nvec_power_driver);
445
446 MODULE_AUTHOR("Ilya Petrov <ilya.muromec@gmail.com>");
447 MODULE_LICENSE("GPL");
448 MODULE_DESCRIPTION("NVEC battery and AC driver");
449 MODULE_ALIAS("platform:nvec-power");