GNU Linux-libre 4.19.286-gnu1
[releases.git] / drivers / thermal / cpu_cooling.c
1 /*
2  *  linux/drivers/thermal/cpu_cooling.c
3  *
4  *  Copyright (C) 2012  Samsung Electronics Co., Ltd(http://www.samsung.com)
5  *  Copyright (C) 2012  Amit Daniel <amit.kachhap@linaro.org>
6  *
7  *  Copyright (C) 2014  Viresh Kumar <viresh.kumar@linaro.org>
8  *
9  * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
10  *  This program is free software; you can redistribute it and/or modify
11  *  it under the terms of the GNU General Public License as published by
12  *  the Free Software Foundation; version 2 of the License.
13  *
14  *  This program is distributed in the hope that it will be useful, but
15  *  WITHOUT ANY WARRANTY; without even the implied warranty of
16  *  MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU
17  *  General Public License for more details.
18  *
19  *  You should have received a copy of the GNU General Public License along
20  *  with this program; if not, write to the Free Software Foundation, Inc.,
21  *  59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
22  *
23  * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
24  */
25 #include <linux/module.h>
26 #include <linux/thermal.h>
27 #include <linux/cpufreq.h>
28 #include <linux/err.h>
29 #include <linux/idr.h>
30 #include <linux/pm_opp.h>
31 #include <linux/slab.h>
32 #include <linux/cpu.h>
33 #include <linux/cpu_cooling.h>
34
35 #include <trace/events/thermal.h>
36
37 /*
38  * Cooling state <-> CPUFreq frequency
39  *
40  * Cooling states are translated to frequencies throughout this driver and this
41  * is the relation between them.
42  *
43  * Highest cooling state corresponds to lowest possible frequency.
44  *
45  * i.e.
46  *      level 0 --> 1st Max Freq
47  *      level 1 --> 2nd Max Freq
48  *      ...
49  */
50
51 /**
52  * struct freq_table - frequency table along with power entries
53  * @frequency:  frequency in KHz
54  * @power:      power in mW
55  *
56  * This structure is built when the cooling device registers and helps
57  * in translating frequency to power and vice versa.
58  */
59 struct freq_table {
60         u32 frequency;
61         u32 power;
62 };
63
64 /**
65  * struct time_in_idle - Idle time stats
66  * @time: previous reading of the absolute time that this cpu was idle
67  * @timestamp: wall time of the last invocation of get_cpu_idle_time_us()
68  */
69 struct time_in_idle {
70         u64 time;
71         u64 timestamp;
72 };
73
74 /**
75  * struct cpufreq_cooling_device - data for cooling device with cpufreq
76  * @id: unique integer value corresponding to each cpufreq_cooling_device
77  *      registered.
78  * @last_load: load measured by the latest call to cpufreq_get_requested_power()
79  * @cpufreq_state: integer value representing the current state of cpufreq
80  *      cooling devices.
81  * @clipped_freq: integer value representing the absolute value of the clipped
82  *      frequency.
83  * @max_level: maximum cooling level. One less than total number of valid
84  *      cpufreq frequencies.
85  * @freq_table: Freq table in descending order of frequencies
86  * @cdev: thermal_cooling_device pointer to keep track of the
87  *      registered cooling device.
88  * @policy: cpufreq policy.
89  * @node: list_head to link all cpufreq_cooling_device together.
90  * @idle_time: idle time stats
91  *
92  * This structure is required for keeping information of each registered
93  * cpufreq_cooling_device.
94  */
95 struct cpufreq_cooling_device {
96         int id;
97         u32 last_load;
98         unsigned int cpufreq_state;
99         unsigned int clipped_freq;
100         unsigned int max_level;
101         struct freq_table *freq_table;  /* In descending order */
102         struct thermal_cooling_device *cdev;
103         struct cpufreq_policy *policy;
104         struct list_head node;
105         struct time_in_idle *idle_time;
106 };
107
108 static DEFINE_IDA(cpufreq_ida);
109 static DEFINE_MUTEX(cooling_list_lock);
110 static LIST_HEAD(cpufreq_cdev_list);
111
112 /* Below code defines functions to be used for cpufreq as cooling device */
113
114 /**
115  * get_level: Find the level for a particular frequency
116  * @cpufreq_cdev: cpufreq_cdev for which the property is required
117  * @freq: Frequency
118  *
119  * Return: level corresponding to the frequency.
120  */
121 static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev,
122                                unsigned int freq)
123 {
124         struct freq_table *freq_table = cpufreq_cdev->freq_table;
125         unsigned long level;
126
127         for (level = 1; level <= cpufreq_cdev->max_level; level++)
128                 if (freq > freq_table[level].frequency)
129                         break;
130
131         return level - 1;
132 }
133
134 /**
135  * cpufreq_thermal_notifier - notifier callback for cpufreq policy change.
136  * @nb: struct notifier_block * with callback info.
137  * @event: value showing cpufreq event for which this function invoked.
138  * @data: callback-specific data
139  *
140  * Callback to hijack the notification on cpufreq policy transition.
141  * Every time there is a change in policy, we will intercept and
142  * update the cpufreq policy with thermal constraints.
143  *
144  * Return: 0 (success)
145  */
146 static int cpufreq_thermal_notifier(struct notifier_block *nb,
147                                     unsigned long event, void *data)
148 {
149         struct cpufreq_policy *policy = data;
150         unsigned long clipped_freq;
151         struct cpufreq_cooling_device *cpufreq_cdev;
152
153         if (event != CPUFREQ_ADJUST)
154                 return NOTIFY_DONE;
155
156         mutex_lock(&cooling_list_lock);
157         list_for_each_entry(cpufreq_cdev, &cpufreq_cdev_list, node) {
158                 /*
159                  * A new copy of the policy is sent to the notifier and can't
160                  * compare that directly.
161                  */
162                 if (policy->cpu != cpufreq_cdev->policy->cpu)
163                         continue;
164
165                 /*
166                  * policy->max is the maximum allowed frequency defined by user
167                  * and clipped_freq is the maximum that thermal constraints
168                  * allow.
169                  *
170                  * If clipped_freq is lower than policy->max, then we need to
171                  * readjust policy->max.
172                  *
173                  * But, if clipped_freq is greater than policy->max, we don't
174                  * need to do anything.
175                  */
176                 clipped_freq = cpufreq_cdev->clipped_freq;
177
178                 if (policy->max > clipped_freq)
179                         cpufreq_verify_within_limits(policy, 0, clipped_freq);
180                 break;
181         }
182         mutex_unlock(&cooling_list_lock);
183
184         return NOTIFY_OK;
185 }
186
187 /**
188  * update_freq_table() - Update the freq table with power numbers
189  * @cpufreq_cdev:       the cpufreq cooling device in which to update the table
190  * @capacitance: dynamic power coefficient for these cpus
191  *
192  * Update the freq table with power numbers.  This table will be used in
193  * cpu_power_to_freq() and cpu_freq_to_power() to convert between power and
194  * frequency efficiently.  Power is stored in mW, frequency in KHz.  The
195  * resulting table is in descending order.
196  *
197  * Return: 0 on success, -EINVAL if there are no OPPs for any CPUs,
198  * or -ENOMEM if we run out of memory.
199  */
200 static int update_freq_table(struct cpufreq_cooling_device *cpufreq_cdev,
201                              u32 capacitance)
202 {
203         struct freq_table *freq_table = cpufreq_cdev->freq_table;
204         struct dev_pm_opp *opp;
205         struct device *dev = NULL;
206         int num_opps = 0, cpu = cpufreq_cdev->policy->cpu, i;
207
208         dev = get_cpu_device(cpu);
209         if (unlikely(!dev)) {
210                 dev_warn(&cpufreq_cdev->cdev->device,
211                          "No cpu device for cpu %d\n", cpu);
212                 return -ENODEV;
213         }
214
215         num_opps = dev_pm_opp_get_opp_count(dev);
216         if (num_opps < 0)
217                 return num_opps;
218
219         /*
220          * The cpufreq table is also built from the OPP table and so the count
221          * should match.
222          */
223         if (num_opps != cpufreq_cdev->max_level + 1) {
224                 dev_warn(dev, "Number of OPPs not matching with max_levels\n");
225                 return -EINVAL;
226         }
227
228         for (i = 0; i <= cpufreq_cdev->max_level; i++) {
229                 unsigned long freq = freq_table[i].frequency * 1000;
230                 u32 freq_mhz = freq_table[i].frequency / 1000;
231                 u64 power;
232                 u32 voltage_mv;
233
234                 /*
235                  * Find ceil frequency as 'freq' may be slightly lower than OPP
236                  * freq due to truncation while converting to kHz.
237                  */
238                 opp = dev_pm_opp_find_freq_ceil(dev, &freq);
239                 if (IS_ERR(opp)) {
240                         dev_err(dev, "failed to get opp for %lu frequency\n",
241                                 freq);
242                         return -EINVAL;
243                 }
244
245                 voltage_mv = dev_pm_opp_get_voltage(opp) / 1000;
246                 dev_pm_opp_put(opp);
247
248                 /*
249                  * Do the multiplication with MHz and millivolt so as
250                  * to not overflow.
251                  */
252                 power = (u64)capacitance * freq_mhz * voltage_mv * voltage_mv;
253                 do_div(power, 1000000000);
254
255                 /* power is stored in mW */
256                 freq_table[i].power = power;
257         }
258
259         return 0;
260 }
261
262 static u32 cpu_freq_to_power(struct cpufreq_cooling_device *cpufreq_cdev,
263                              u32 freq)
264 {
265         int i;
266         struct freq_table *freq_table = cpufreq_cdev->freq_table;
267
268         for (i = 1; i <= cpufreq_cdev->max_level; i++)
269                 if (freq > freq_table[i].frequency)
270                         break;
271
272         return freq_table[i - 1].power;
273 }
274
275 static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_cdev,
276                              u32 power)
277 {
278         int i;
279         struct freq_table *freq_table = cpufreq_cdev->freq_table;
280
281         for (i = 0; i < cpufreq_cdev->max_level; i++)
282                 if (power >= freq_table[i].power)
283                         break;
284
285         return freq_table[i].frequency;
286 }
287
288 /**
289  * get_load() - get load for a cpu since last updated
290  * @cpufreq_cdev:       &struct cpufreq_cooling_device for this cpu
291  * @cpu:        cpu number
292  * @cpu_idx:    index of the cpu in time_in_idle*
293  *
294  * Return: The average load of cpu @cpu in percentage since this
295  * function was last called.
296  */
297 static u32 get_load(struct cpufreq_cooling_device *cpufreq_cdev, int cpu,
298                     int cpu_idx)
299 {
300         u32 load;
301         u64 now, now_idle, delta_time, delta_idle;
302         struct time_in_idle *idle_time = &cpufreq_cdev->idle_time[cpu_idx];
303
304         now_idle = get_cpu_idle_time(cpu, &now, 0);
305         delta_idle = now_idle - idle_time->time;
306         delta_time = now - idle_time->timestamp;
307
308         if (delta_time <= delta_idle)
309                 load = 0;
310         else
311                 load = div64_u64(100 * (delta_time - delta_idle), delta_time);
312
313         idle_time->time = now_idle;
314         idle_time->timestamp = now;
315
316         return load;
317 }
318
319 /**
320  * get_dynamic_power() - calculate the dynamic power
321  * @cpufreq_cdev:       &cpufreq_cooling_device for this cdev
322  * @freq:       current frequency
323  *
324  * Return: the dynamic power consumed by the cpus described by
325  * @cpufreq_cdev.
326  */
327 static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_cdev,
328                              unsigned long freq)
329 {
330         u32 raw_cpu_power;
331
332         raw_cpu_power = cpu_freq_to_power(cpufreq_cdev, freq);
333         return (raw_cpu_power * cpufreq_cdev->last_load) / 100;
334 }
335
336 /* cpufreq cooling device callback functions are defined below */
337
338 /**
339  * cpufreq_get_max_state - callback function to get the max cooling state.
340  * @cdev: thermal cooling device pointer.
341  * @state: fill this variable with the max cooling state.
342  *
343  * Callback for the thermal cooling device to return the cpufreq
344  * max cooling state.
345  *
346  * Return: 0 on success, an error code otherwise.
347  */
348 static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
349                                  unsigned long *state)
350 {
351         struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
352
353         *state = cpufreq_cdev->max_level;
354         return 0;
355 }
356
357 /**
358  * cpufreq_get_cur_state - callback function to get the current cooling state.
359  * @cdev: thermal cooling device pointer.
360  * @state: fill this variable with the current cooling state.
361  *
362  * Callback for the thermal cooling device to return the cpufreq
363  * current cooling state.
364  *
365  * Return: 0 on success, an error code otherwise.
366  */
367 static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
368                                  unsigned long *state)
369 {
370         struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
371
372         *state = cpufreq_cdev->cpufreq_state;
373
374         return 0;
375 }
376
377 /**
378  * cpufreq_set_cur_state - callback function to set the current cooling state.
379  * @cdev: thermal cooling device pointer.
380  * @state: set this variable to the current cooling state.
381  *
382  * Callback for the thermal cooling device to change the cpufreq
383  * current cooling state.
384  *
385  * Return: 0 on success, an error code otherwise.
386  */
387 static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
388                                  unsigned long state)
389 {
390         struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
391         unsigned int clip_freq;
392
393         /* Request state should be less than max_level */
394         if (WARN_ON(state > cpufreq_cdev->max_level))
395                 return -EINVAL;
396
397         /* Check if the old cooling action is same as new cooling action */
398         if (cpufreq_cdev->cpufreq_state == state)
399                 return 0;
400
401         clip_freq = cpufreq_cdev->freq_table[state].frequency;
402         cpufreq_cdev->cpufreq_state = state;
403         cpufreq_cdev->clipped_freq = clip_freq;
404
405         cpufreq_update_policy(cpufreq_cdev->policy->cpu);
406
407         return 0;
408 }
409
410 /**
411  * cpufreq_get_requested_power() - get the current power
412  * @cdev:       &thermal_cooling_device pointer
413  * @tz:         a valid thermal zone device pointer
414  * @power:      pointer in which to store the resulting power
415  *
416  * Calculate the current power consumption of the cpus in milliwatts
417  * and store it in @power.  This function should actually calculate
418  * the requested power, but it's hard to get the frequency that
419  * cpufreq would have assigned if there were no thermal limits.
420  * Instead, we calculate the current power on the assumption that the
421  * immediate future will look like the immediate past.
422  *
423  * We use the current frequency and the average load since this
424  * function was last called.  In reality, there could have been
425  * multiple opps since this function was last called and that affects
426  * the load calculation.  While it's not perfectly accurate, this
427  * simplification is good enough and works.  REVISIT this, as more
428  * complex code may be needed if experiments show that it's not
429  * accurate enough.
430  *
431  * Return: 0 on success, -E* if getting the static power failed.
432  */
433 static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
434                                        struct thermal_zone_device *tz,
435                                        u32 *power)
436 {
437         unsigned long freq;
438         int i = 0, cpu;
439         u32 total_load = 0;
440         struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
441         struct cpufreq_policy *policy = cpufreq_cdev->policy;
442         u32 *load_cpu = NULL;
443
444         freq = cpufreq_quick_get(policy->cpu);
445
446         if (trace_thermal_power_cpu_get_power_enabled()) {
447                 u32 ncpus = cpumask_weight(policy->related_cpus);
448
449                 load_cpu = kcalloc(ncpus, sizeof(*load_cpu), GFP_KERNEL);
450         }
451
452         for_each_cpu(cpu, policy->related_cpus) {
453                 u32 load;
454
455                 if (cpu_online(cpu))
456                         load = get_load(cpufreq_cdev, cpu, i);
457                 else
458                         load = 0;
459
460                 total_load += load;
461                 if (load_cpu)
462                         load_cpu[i] = load;
463
464                 i++;
465         }
466
467         cpufreq_cdev->last_load = total_load;
468
469         *power = get_dynamic_power(cpufreq_cdev, freq);
470
471         if (load_cpu) {
472                 trace_thermal_power_cpu_get_power(policy->related_cpus, freq,
473                                                   load_cpu, i, *power);
474
475                 kfree(load_cpu);
476         }
477
478         return 0;
479 }
480
481 /**
482  * cpufreq_state2power() - convert a cpu cdev state to power consumed
483  * @cdev:       &thermal_cooling_device pointer
484  * @tz:         a valid thermal zone device pointer
485  * @state:      cooling device state to be converted
486  * @power:      pointer in which to store the resulting power
487  *
488  * Convert cooling device state @state into power consumption in
489  * milliwatts assuming 100% load.  Store the calculated power in
490  * @power.
491  *
492  * Return: 0 on success, -EINVAL if the cooling device state could not
493  * be converted into a frequency or other -E* if there was an error
494  * when calculating the static power.
495  */
496 static int cpufreq_state2power(struct thermal_cooling_device *cdev,
497                                struct thermal_zone_device *tz,
498                                unsigned long state, u32 *power)
499 {
500         unsigned int freq, num_cpus;
501         struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
502
503         /* Request state should be less than max_level */
504         if (WARN_ON(state > cpufreq_cdev->max_level))
505                 return -EINVAL;
506
507         num_cpus = cpumask_weight(cpufreq_cdev->policy->cpus);
508
509         freq = cpufreq_cdev->freq_table[state].frequency;
510         *power = cpu_freq_to_power(cpufreq_cdev, freq) * num_cpus;
511
512         return 0;
513 }
514
515 /**
516  * cpufreq_power2state() - convert power to a cooling device state
517  * @cdev:       &thermal_cooling_device pointer
518  * @tz:         a valid thermal zone device pointer
519  * @power:      power in milliwatts to be converted
520  * @state:      pointer in which to store the resulting state
521  *
522  * Calculate a cooling device state for the cpus described by @cdev
523  * that would allow them to consume at most @power mW and store it in
524  * @state.  Note that this calculation depends on external factors
525  * such as the cpu load or the current static power.  Calling this
526  * function with the same power as input can yield different cooling
527  * device states depending on those external factors.
528  *
529  * Return: 0 on success, -ENODEV if no cpus are online or -EINVAL if
530  * the calculated frequency could not be converted to a valid state.
531  * The latter should not happen unless the frequencies available to
532  * cpufreq have changed since the initialization of the cpu cooling
533  * device.
534  */
535 static int cpufreq_power2state(struct thermal_cooling_device *cdev,
536                                struct thermal_zone_device *tz, u32 power,
537                                unsigned long *state)
538 {
539         unsigned int cur_freq, target_freq;
540         u32 last_load, normalised_power;
541         struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
542         struct cpufreq_policy *policy = cpufreq_cdev->policy;
543
544         cur_freq = cpufreq_quick_get(policy->cpu);
545         power = power > 0 ? power : 0;
546         last_load = cpufreq_cdev->last_load ?: 1;
547         normalised_power = (power * 100) / last_load;
548         target_freq = cpu_power_to_freq(cpufreq_cdev, normalised_power);
549
550         *state = get_level(cpufreq_cdev, target_freq);
551         trace_thermal_power_cpu_limit(policy->related_cpus, target_freq, *state,
552                                       power);
553         return 0;
554 }
555
556 /* Bind cpufreq callbacks to thermal cooling device ops */
557
558 static struct thermal_cooling_device_ops cpufreq_cooling_ops = {
559         .get_max_state = cpufreq_get_max_state,
560         .get_cur_state = cpufreq_get_cur_state,
561         .set_cur_state = cpufreq_set_cur_state,
562 };
563
564 static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = {
565         .get_max_state          = cpufreq_get_max_state,
566         .get_cur_state          = cpufreq_get_cur_state,
567         .set_cur_state          = cpufreq_set_cur_state,
568         .get_requested_power    = cpufreq_get_requested_power,
569         .state2power            = cpufreq_state2power,
570         .power2state            = cpufreq_power2state,
571 };
572
573 /* Notifier for cpufreq policy change */
574 static struct notifier_block thermal_cpufreq_notifier_block = {
575         .notifier_call = cpufreq_thermal_notifier,
576 };
577
578 static unsigned int find_next_max(struct cpufreq_frequency_table *table,
579                                   unsigned int prev_max)
580 {
581         struct cpufreq_frequency_table *pos;
582         unsigned int max = 0;
583
584         cpufreq_for_each_valid_entry(pos, table) {
585                 if (pos->frequency > max && pos->frequency < prev_max)
586                         max = pos->frequency;
587         }
588
589         return max;
590 }
591
592 /**
593  * __cpufreq_cooling_register - helper function to create cpufreq cooling device
594  * @np: a valid struct device_node to the cooling device device tree node
595  * @policy: cpufreq policy
596  * Normally this should be same as cpufreq policy->related_cpus.
597  * @capacitance: dynamic power coefficient for these cpus
598  *
599  * This interface function registers the cpufreq cooling device with the name
600  * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
601  * cooling devices. It also gives the opportunity to link the cooling device
602  * with a device tree node, in order to bind it via the thermal DT code.
603  *
604  * Return: a valid struct thermal_cooling_device pointer on success,
605  * on failure, it returns a corresponding ERR_PTR().
606  */
607 static struct thermal_cooling_device *
608 __cpufreq_cooling_register(struct device_node *np,
609                         struct cpufreq_policy *policy, u32 capacitance)
610 {
611         struct thermal_cooling_device *cdev;
612         struct cpufreq_cooling_device *cpufreq_cdev;
613         char dev_name[THERMAL_NAME_LENGTH];
614         unsigned int freq, i, num_cpus;
615         int ret;
616         struct thermal_cooling_device_ops *cooling_ops;
617         bool first;
618
619         if (IS_ERR_OR_NULL(policy)) {
620                 pr_err("%s: cpufreq policy isn't valid: %p\n", __func__, policy);
621                 return ERR_PTR(-EINVAL);
622         }
623
624         i = cpufreq_table_count_valid_entries(policy);
625         if (!i) {
626                 pr_debug("%s: CPUFreq table not found or has no valid entries\n",
627                          __func__);
628                 return ERR_PTR(-ENODEV);
629         }
630
631         cpufreq_cdev = kzalloc(sizeof(*cpufreq_cdev), GFP_KERNEL);
632         if (!cpufreq_cdev)
633                 return ERR_PTR(-ENOMEM);
634
635         cpufreq_cdev->policy = policy;
636         num_cpus = cpumask_weight(policy->related_cpus);
637         cpufreq_cdev->idle_time = kcalloc(num_cpus,
638                                          sizeof(*cpufreq_cdev->idle_time),
639                                          GFP_KERNEL);
640         if (!cpufreq_cdev->idle_time) {
641                 cdev = ERR_PTR(-ENOMEM);
642                 goto free_cdev;
643         }
644
645         /* max_level is an index, not a counter */
646         cpufreq_cdev->max_level = i - 1;
647
648         cpufreq_cdev->freq_table = kmalloc_array(i,
649                                         sizeof(*cpufreq_cdev->freq_table),
650                                         GFP_KERNEL);
651         if (!cpufreq_cdev->freq_table) {
652                 cdev = ERR_PTR(-ENOMEM);
653                 goto free_idle_time;
654         }
655
656         ret = ida_simple_get(&cpufreq_ida, 0, 0, GFP_KERNEL);
657         if (ret < 0) {
658                 cdev = ERR_PTR(ret);
659                 goto free_table;
660         }
661         cpufreq_cdev->id = ret;
662
663         snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
664                  cpufreq_cdev->id);
665
666         /* Fill freq-table in descending order of frequencies */
667         for (i = 0, freq = -1; i <= cpufreq_cdev->max_level; i++) {
668                 freq = find_next_max(policy->freq_table, freq);
669                 cpufreq_cdev->freq_table[i].frequency = freq;
670
671                 /* Warn for duplicate entries */
672                 if (!freq)
673                         pr_warn("%s: table has duplicate entries\n", __func__);
674                 else
675                         pr_debug("%s: freq:%u KHz\n", __func__, freq);
676         }
677
678         if (capacitance) {
679                 ret = update_freq_table(cpufreq_cdev, capacitance);
680                 if (ret) {
681                         cdev = ERR_PTR(ret);
682                         goto remove_ida;
683                 }
684
685                 cooling_ops = &cpufreq_power_cooling_ops;
686         } else {
687                 cooling_ops = &cpufreq_cooling_ops;
688         }
689
690         cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev,
691                                                   cooling_ops);
692         if (IS_ERR(cdev))
693                 goto remove_ida;
694
695         cpufreq_cdev->clipped_freq = cpufreq_cdev->freq_table[0].frequency;
696         cpufreq_cdev->cdev = cdev;
697
698         mutex_lock(&cooling_list_lock);
699         /* Register the notifier for first cpufreq cooling device */
700         first = list_empty(&cpufreq_cdev_list);
701         list_add(&cpufreq_cdev->node, &cpufreq_cdev_list);
702         mutex_unlock(&cooling_list_lock);
703
704         if (first)
705                 cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
706                                           CPUFREQ_POLICY_NOTIFIER);
707
708         return cdev;
709
710 remove_ida:
711         ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
712 free_table:
713         kfree(cpufreq_cdev->freq_table);
714 free_idle_time:
715         kfree(cpufreq_cdev->idle_time);
716 free_cdev:
717         kfree(cpufreq_cdev);
718         return cdev;
719 }
720
721 /**
722  * cpufreq_cooling_register - function to create cpufreq cooling device.
723  * @policy: cpufreq policy
724  *
725  * This interface function registers the cpufreq cooling device with the name
726  * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
727  * cooling devices.
728  *
729  * Return: a valid struct thermal_cooling_device pointer on success,
730  * on failure, it returns a corresponding ERR_PTR().
731  */
732 struct thermal_cooling_device *
733 cpufreq_cooling_register(struct cpufreq_policy *policy)
734 {
735         return __cpufreq_cooling_register(NULL, policy, 0);
736 }
737 EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
738
739 /**
740  * of_cpufreq_cooling_register - function to create cpufreq cooling device.
741  * @policy: cpufreq policy
742  *
743  * This interface function registers the cpufreq cooling device with the name
744  * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
745  * cooling devices. Using this API, the cpufreq cooling device will be
746  * linked to the device tree node provided.
747  *
748  * Using this function, the cooling device will implement the power
749  * extensions by using a simple cpu power model.  The cpus must have
750  * registered their OPPs using the OPP library.
751  *
752  * It also takes into account, if property present in policy CPU node, the
753  * static power consumed by the cpu.
754  *
755  * Return: a valid struct thermal_cooling_device pointer on success,
756  * and NULL on failure.
757  */
758 struct thermal_cooling_device *
759 of_cpufreq_cooling_register(struct cpufreq_policy *policy)
760 {
761         struct device_node *np = of_get_cpu_node(policy->cpu, NULL);
762         struct thermal_cooling_device *cdev = NULL;
763         u32 capacitance = 0;
764
765         if (!np) {
766                 pr_err("cpu_cooling: OF node not available for cpu%d\n",
767                        policy->cpu);
768                 return NULL;
769         }
770
771         if (of_find_property(np, "#cooling-cells", NULL)) {
772                 of_property_read_u32(np, "dynamic-power-coefficient",
773                                      &capacitance);
774
775                 cdev = __cpufreq_cooling_register(np, policy, capacitance);
776                 if (IS_ERR(cdev)) {
777                         pr_err("cpu_cooling: cpu%d is not running as cooling device: %ld\n",
778                                policy->cpu, PTR_ERR(cdev));
779                         cdev = NULL;
780                 }
781         }
782
783         of_node_put(np);
784         return cdev;
785 }
786 EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register);
787
788 /**
789  * cpufreq_cooling_unregister - function to remove cpufreq cooling device.
790  * @cdev: thermal cooling device pointer.
791  *
792  * This interface function unregisters the "thermal-cpufreq-%x" cooling device.
793  */
794 void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
795 {
796         struct cpufreq_cooling_device *cpufreq_cdev;
797         bool last;
798
799         if (!cdev)
800                 return;
801
802         cpufreq_cdev = cdev->devdata;
803
804         mutex_lock(&cooling_list_lock);
805         list_del(&cpufreq_cdev->node);
806         /* Unregister the notifier for the last cpufreq cooling device */
807         last = list_empty(&cpufreq_cdev_list);
808         mutex_unlock(&cooling_list_lock);
809
810         if (last)
811                 cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block,
812                                             CPUFREQ_POLICY_NOTIFIER);
813
814         thermal_cooling_device_unregister(cpufreq_cdev->cdev);
815         ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
816         kfree(cpufreq_cdev->idle_time);
817         kfree(cpufreq_cdev->freq_table);
818         kfree(cpufreq_cdev);
819 }
820 EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister);